2861878 Phoenix Contact IB IL 24/230 DOR4/W-PAC
Item #: 753023762
Safety Relay
Inline digital output terminal complete with accessories (plug and labeling field) 4 relay PDT gold contacts 5 - 253 V AC 3 A
Inline digital output terminal complete with accessories (plug and labeling field) 4 relay PDT gold contacts 5 - 253 V AC 3 A
- Floating connections for 4 actuators
- Safe isolation
- Diagnostic and status indicators
2700453 Phoenix Contact NLC-055-024D-08I-04QTP-00A
Item #: 753039751
Screw
Optional communication modules provide network or serial connectivity. Optional Operator Panel provides user interface. Programming is via nanoNavigator.
Optional communication modules provide network or serial connectivity. Optional Operator Panel provides user interface. Programming is via nanoNavigator.
2701040 Phoenix Contact NLC-IO-2AI-2AO-01
Item #: 753039753
Surge Protection Base Element
I/O extension module for use with Nanoline base unit. Equipped with 2 analog input (0...10 V DC -10...+10 V DC 0/4...20 mA) and 2 analog output (0...10 V DC 0/4...20 mA) channels. A maximum of three I/O extension modules can be attached to a base unit.
I/O extension module for use with Nanoline base unit. Equipped with 2 analog input (0...10 V DC -10...+10 V DC 0/4...20 mA) and 2 analog output (0...10 V DC 0/4...20 mA) channels. A maximum of three I/O extension modules can be attached to a base unit.
- A system may have up to 8 analog inputs and 8 analog outputs
- Automatically recognized by nanoNavigator
- I/O modules are electrically isolated
2878036 Phoenix Contact IB IL AO 4/8/U/BP-PAC
Item #: 900055891
Terminal Strip Marker Carrier
Inline analog output terminal complete with accessories (connector plug and labeling field) 8 outputs 0 - 10 V 10 V 2-wire connection technology
Inline analog output terminal complete with accessories (connector plug and labeling field) 8 outputs 0 - 10 V 10 V 2-wire connection technology
- Short update time of < 1 ms
- Short-circuit-proof current outputs
- Bipolar outputs
2692306 Phoenix Contact IB IL 24 DI 4-2MBD-PAC
Item #: 753039390
Safety Relay
The digital Inline input terminals are designed for the connection of digital signals as are supplied from control switches, limit switches or proximity switches. All the typical applications are covered by the standard automation terminals. The I/O equipment is connected by a simple or an extended Inline plug, depending on the number of channels. The multi-wire connection method is available in both cases.
The digital Inline input terminals are designed for the connection of digital signals as are supplied from control switches, limit switches or proximity switches. All the typical applications are covered by the standard automation terminals. The I/O equipment is connected by a simple or an extended Inline plug, depending on the number of channels. The multi-wire connection method is available in both cases.
- 4 digital inputs
- Connection of sensors in 2 and 3-wire technology
- Maximum permissible load current per sensor: 250 mA
- Maximum permissible load current from the terminal: 1 A
- Diagnostic and status indicators
2700172 Phoenix Contact IB IL 24 DO8/HD-PAC
Item #: 900114652
Solid State Relay Module
Inline digital output terminal complete with accessories (connector plug and labeling field) 8 outputs 24 V DC 500 mA 1-wire connection technology
Inline digital output terminal complete with accessories (connector plug and labeling field) 8 outputs 24 V DC 500 mA 1-wire connection technology
- Connection of actuators in single-wire technology
- Short-circuit-proof and overload-protected outputs
- Diagnostic and status indicators
2700173 Phoenix Contact IB IL 24 DI8/HD-PAC
Item #: 753039740
Relay Module
Inline digital input terminal complete with accessories (connector plug and labeling field) 8 inputs 24 V DC 1-wire connection technology
Inline digital input terminal complete with accessories (connector plug and labeling field) 8 inputs 24 V DC 1-wire connection technology
- 8 digital inputs
- Connection of sensors in single-wire technology
- Diagnostic and status indicators
2700458 Phoenix Contact IB IL AI 4/I-PAC
Item #: 753039743
Screwdriver
Inline analog input terminal complete with accessories (plug and labeling field) inputs: 0-20 mA 4-20 mA 2-wire connection method
Inline analog input terminal complete with accessories (plug and labeling field) inputs: 0-20 mA 4-20 mA 2-wire connection method
- 4 analog differential input channels for connecting current signals
- Connection of sensors in 2-wire technology
- Mean-value generation of the inputs
2700459 Phoenix Contact IB IL AI 4/U-PAC
Item #: 753039744
Safety Relay
Inline analog input terminal complete with accessories (plug and labeling field) inputs: 0-10 V 10 V 2-wire connection method
Inline analog input terminal complete with accessories (plug and labeling field) inputs: 0-10 V 10 V 2-wire connection method
- 4 analog, bipolar input channels for the connection of voltage signals
- Connection of sensors in 2-wire technology
- Mean-value generation of the inputs
2700775 Phoenix Contact IB IL AO 2/UI-PAC
Item #: 753039745
Wireless Module
Inline analog output terminal complete with accessories (plug plug and labeling field) 2 outputs 0-20 mA 4-20 mA 20 mA 0-10 V 10 V 2-wire connection method
Inline analog output terminal complete with accessories (plug plug and labeling field) 2 outputs 0-20 mA 4-20 mA 20 mA 0-10 V 10 V 2-wire connection method
- 2 analog output channels
- Connection of actuators in 2-wire technology
- Diagnostic and status indicators
2701124 Phoenix Contact NLC-COM-ENET-MB1
Item #: 900081130
Connector
Ethernet communication module. Allows the Nanoline controller to be connected to an Ethernet operating as a Modbus TCP Server.
Ethernet communication module. Allows the Nanoline controller to be connected to an Ethernet operating as a Modbus TCP Server.
- Enables all I/O points, registers, timers, counters, program flags, and system flags to be read and written remotely
- Watchdog timer monitors communication, providing either a warning or fault
2701140 Phoenix Contact NLC-OP1-MKT
Item #: 900080834
Passive Isolator
Operator panel is your interface for interacting with the nanoline system.
Operator panel is your interface for interacting with the nanoline system.
- Operator panel can be integrated in the logic module or installed remotely on a panel
- Hot swappable design enables use as a service tool
2701153 Phoenix Contact NLC-MOD-RTC
Item #: 900080831
Feed-Through Terminal Block
Real-time clock
Real-time clock
- Optional on NLC-050... base units, standard on NLC-055 base units
- Allows time and date comparisons within a project
- Can be set via operator panel or nanoNavigator
2701166 Phoenix Contact NLC-MOD-MEM 032K
Item #: 753039681
Inline Function Terminal
Memory module
Memory module
- From a PC to one or more Nanoline controllers without a direct connection
- From one controller to another without a direct connection
- From a controller to a replacement controller
2701179 Phoenix Contact NLC-MOD-RS232
Item #: 753039707
Feed-Through Terminal Block
RS-232 connection for data transfer or software configuration
RS-232 connection for data transfer or software configuration
- A watchdog timer monitors communication, providing either a warning or fault
- Serial modules provide a PC connection for configuration purposes and downloading/uploading projects to a basic unit
2701250 Phoenix Contact NLC-OP1-MKT-BASE
Item #: 753039688
Jumper
Panel to mount in base unit RJ-45 connector for remote Operator Panel
Panel to mount in base unit RJ-45 connector for remote Operator Panel
2701328 Phoenix Contact NLC-IO-03I-04QRD-05A
Item #: 900095570
Surge Protection Plug
I/O extension module for use with Nanoline 24 V DC base unit. Equipped with 3 digital input and 4 5 A relay output channels. A maximum of three I/O extension modules can be attached to a base unit.
I/O extension module for use with Nanoline 24 V DC base unit. Equipped with 3 digital input and 4 5 A relay output channels. A maximum of three I/O extension modules can be attached to a base unit.
- Automatically recognized by the firmware
- I/O modules are electrically isolated
- Up to 3 modules can be added to the right side of a base unit
- Can be powered from a secondary power supply
2861250 Phoenix Contact IB IL 24 DI 16-PAC
Item #: 753023764
Safety Relay
Inline digital input terminal complete with accessories (connector plug and labeling field) 16 inputs 24 V DC 2- 3-wire connection technology
Inline digital input terminal complete with accessories (connector plug and labeling field) 16 inputs 24 V DC 2- 3-wire connection technology
- Connection of sensors in 2 and 3-wire technology
- Diagnostic and status indicators
- Approved for use in potentially explosive areas
2861263 Phoenix Contact IB IL 24 DO 2-2A-PAC
Item #: 753023765
Safety Relay
Inline digital output terminal block complete with accessories (plug and labeling field) 2 outputs 24 V DC 2 A 4-wire connection method
Inline digital output terminal block complete with accessories (plug and labeling field) 2 outputs 24 V DC 2 A 4-wire connection method
- 2 digital outputs
- Connection of actuators in 2, 3, and 4-wire technology
- Short-circuit-proof and overload-protected outputs
- Diagnostic and status indicators
2861292 Phoenix Contact IB IL 24 DO 16-PAC
Item #: 753023768
Safety Relay
Inline digital output terminal complete with accessories (connector plug and labeling field) 16 outputs 24 V DC 500 mA 3-wire connection technology
Inline digital output terminal complete with accessories (connector plug and labeling field) 16 outputs 24 V DC 500 mA 3-wire connection technology
- 16 digital outputs
- Connection of actuators in 2 and 3-wire technology
- Short-circuit-proof and overload-protected outputs
2861302 Phoenix Contact IB IL AI 2/SF-PAC
Item #: 753023769
Diode Block
Inline analog input terminal complete with accessories (connector plug and labeling field) 2 inputs 0 - 20 mA 4 - 20 mA 20 mA 0 - 10 V 10 V 2-wire connection technology
Inline analog input terminal complete with accessories (connector plug and labeling field) 2 inputs 0 - 20 mA 4 - 20 mA 20 mA 0 - 10 V 10 V 2-wire connection technology
- High measuring accuracy
- Excellent interference suppression and common mode rejection
- Integrated short-circuit-proof sensor supply